Mechanical testing of scapular neck fracture fixation using a synthetic bone model
Trauma can fracture the scapular neck. Typically, a single plate along the lateral scapula border affixes the glenoid fragment to the scapula. This method is limited by difficulty in screw placement, frequent excessive soft tissue dissection, and risk for neurovascular injury. Substituting 2 smaller plates bridging the scapular neck mitigates these limitations, but no comparative mechanical data between techniques exists. Therefore, we compared the mechanical properties of two constructs securing a simulated scapular neck fracture.